P0904HN LZS 1500-3FOX industrial control spare parts card module
Technical data of product parameters
This P0904HN LZS 1500-3FOX configures the module (write) or indicates the configuration
state of the module (read). A “1” indicates that the module is configured.
Note that until the module is configured, reading from addresses 0
through 11 (B in Hex) will produce an attention status.
Bit 1: This bit (write “1”) forces the module into the error state, resulting in the
error LED being lit. The read of bit “1” indicates that there is an internal
module error, or the Controller has forced the module into the error
state. The state of this bit is always reflected by the module’s Internal
Error LED. Whenever this bit is set, an attention status is returned to the P0904HN LZS 1500-3FOX
Controller when addresses 0 through 11 (B in Hex) are read.
Bits 2-3: These bits are not used and are read as “0” under normal operation.
Bit 4: This bit (read) indicates that the module is in the “Warming” state. This
state exists after power up and terminates after 8.16 seconds. The module will be in the error condition during the warm up period. Bits 5-6: These bits are not used and are read as “0” under normal operation.
This bit (read) is the result of a checksum test of the EEPROM. A failure
of this test can indicate a bad EEPROM, but it typically indicates that
the module has not been calibrated. A “0” indicates that there is no error
condition. If an error is present, the module error LED is lit. The point
fault bit will also be set since all the point data is not calibrated. The “1”
state of this bit indicates an unrecoverable error condition in the field.
Bit 8: The status of this bit (read) indicates the conversion rate of the module,
write to this bit configures the conversion rate of A/D converters as
shown below.This bit (write) is used to initiate self-calibration. The sampling rate during self-calibration will be 2 per second. The status (read) bit is not used P0904HN LZS 1500-3FOX
and is read as “0” under normal operation.
Bit 12: This bit is not used and is read as “0” under normal operation.
Bit 13: This bit (read) indicates that the module has internal memory error
(FLASH checksum, Register or Static RAM error). If this error is
present, the module error LED is lit, the point fault bit will also be set
since the condition of the module is undetermined.
Bit 14: This bit is not used and is read as “0” under normal operation
Product picture display
bout us service idea
The company takes production suspension control system parts and components as its dominant products
As long as it is what you want, I can help you find it! Good price! Our purpose:
Build customer relationship with sincerity
Obtain customer satisfaction through service
Win the trust of customers with products
Improve work efficiency with actions
Please contact us for the products you need urgently!
You can’t find the product. Please contact us!
Products you can’t buy. Please contact us!
Email: onewwww@foxmail.com
Introduction to main products
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules/cards, controllers, touch screens, servo drives.
Advantages: supply imported original products, professional discontinued parts, fast delivery, accurate delivery time,
Main brands include ABB Bailey, GE/FANC, FOXBORO, Invensys TRICONEX, Bentley BENTLY, A-B Rockwell, Emerson EMERSON, OVATION, MOTOROLA, XYVOM, Honeywell HONEYWELL, Rexroth, KUKA, NI, DEIF, Yokogawa, Woodward WOODWARD, Ryan, Schneider SCHNEIDER, Yaskawa, Moog MOOG, PROSOFT and other brands
reminder
For more products, please contact the email for inquiry onewwww@foxmail.com
This article from the temporal Ming sheng automation equipment co., LTD.,
link: http:www.onewwww.com
Reviews
There are no reviews yet.