PROSOFT MVI56-PDPS spare contact input module

Status: In Stock

Warranty: Seven day acceptance period, one year warranty period

Delivery period: 1-3 working days

Advantages: supply of imported genuine products, professional off production accessories, fast delivery and accurate delivery

Main products: Focus on DCS, PLC, robot control system and large servo system. Main products: various modules/cards, controllers, touch screens, servo drives.

Model :MVI56-PDPS

PROSOFT MVI56-PDPS spare contact input module

Technical data of product parameters

MVI56-PDPS on-board power supply provides current limited contact wetting voltage if
the contact is open. If the contact closes, current is drawn from the +10V supply
which turns on the associated opto-isolator; thereby, relaying a closed contact state
to the I/O bus. The opto-isolators and the isolation provided by the 10V and 48 Volt
power supply provide high dielectric isolation between the field side and the logic MVI56-PDPS
or I/O bus side.
There are two methods of wiring field devices to the termination block as shown in
Figure 21-4. Each field contact may have a separate input and return line as shown
for channel 1. Alternatively, field contacts wired to the same module may share a
return line as shown for channels 2 and 3. For either wiring method, do not tie the
contact return line to earth ground or a ground fault condition will occur, as well as MVI56-PDPS
a degradation of the common mode surge protection.
Ground fault detection circuitry on the Sequence of Events module with Contact
Inputs activates when the input or return line for any channel finds a low impedance
(<5 K ohms) path to earth ground. A single wire with a ground fault will not cause
an error in the point data, but multiple ground faults, if they include input and return
lines, could cause faulty data (that is, channels appearing as if their contacts are MVI56-PDPS
closed when they are really open)When a ground fault occurs, the external error LED lights, and the GND Fault bit
11 in the Status Register is set. If the GND Fault Attention Enable bit 8 is set in the
Configuration Register, a ground fault is seen as a catastrophic error causing an
attention status to be sent back to the Controller. See Figure 21-4 for ground fault
detection circuitry.MVI56-PDPS


Product picture display

PROSOFT MVI56-PDPS spare contact input module

 


bout us service idea

The company takes production suspension control system parts and components as its dominant products

As long as it is what you want, I can help you find it! Good price! Our purpose:

Build customer relationship with sincerity

Obtain customer satisfaction through service

Win the trust of customers with products

Improve work efficiency with actions

Please contact us for the products you need urgently!

You can’t find the product. Please contact us!

Products you can’t buy. Please contact us!

Email: onewwww@foxmail.com


Introduction to main products

Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules/cards, controllers, touch screens, servo drives.

Advantages: supply imported original products, professional discontinued parts, fast delivery, accurate delivery time,

Main brands include ABB Bailey, GE/FANC, FOXBORO, Invensys TRICONEX, Bentley BENTLY, A-B Rockwell, Emerson EMERSON, OVATION, MOTOROLA, XYVOM, Honeywell HONEYWELL, Rexroth, KUKA, NI, DEIF, Yokogawa, Woodward WOODWARD, Ryan, Schneider SCHNEIDER, Yaskawa, Moog MOOG, PROSOFT and other brands


reminder

For more products, please contact the email for inquiry onewwww@foxmail.com

This article from the temporal Ming sheng automation equipment co., LTD.,

link: http:www.onewwww.com

PROSOFT MVI56-PDPS spare contact input module1

    Reviews

    There are no reviews yet.

    Be the first to review “PROSOFT MVI56-PDPS spare contact input module”

    Your email address will not be published. Required fields are marked *

    Back to Top
    Product has been added to your cart