TRICONEX 2000417 Module Inventory

Status: In Stock

Warranty: Seven day acceptance period, one year warranty period

Delivery period: 1-3 working days

Advantages: supply of imported genuine products, professional off production accessories, fast delivery and accurate delivery

Main products: Focus on DCS, PLC, robot control system and large servo system. Main products: various modules/cards, controllers, touch screens, servo drives.

Model : 2000417

TRICONEX 2000417 Module Inventory

Technical data of product parameters

The most common waste heat recovery systems in TRICONEX 2000417 are steam and hot water. The maximum jacket water outlet temperature for most engines is 210 ° F. Other engines may operate at temperatures of 260 ° F. The engine must be specifically configured to operate at higher temperatures.
TRICONEX 2000417 However, for most applications, a temperature of 210 F is sufficient to meet all requirements. Jacket water can generate low pressure steam from 250 ° F to 260 ° F. This temperature (for properly configured engines) can be generated by cooling applications where steam is formed in the engine water jacket and then rises due to the density difference between water and steam. Before considering a cogeneration plant, it is best to discuss with a professional electrical contractor to determine what jacket water configuration is required.
Another method of generating low-pressure steam from the engine’s jacket water is the circulation of water pumped through the cooling system. The liquid water from the drum is pumped through the engine, and the heat of the jacket water is converted into steam when it enters the drum chamber.
Steam from 15 PSIG to 250 PSIG can also be generated from the exhaust gases of any gas turbine or diesel generator set. Most exhaust systems are also designed with optional combustion steam boilers that are used by wastegate valves. The waste heat can be used together with the heat of the jacket water to generate 15 PSIG of steam, or can be used in a separate system to generate higher pressure steam.
For reciprocating (piston) engines, approximately 34% of the heat input is recovered as power and 66% is not recovered. All heat emitted into the jacket water is recyclable, and approximately 40% to 60% of the heat emitted into the exhaust outflow is recyclable, depending on the engine. In some cases, although rarely, aftercooler heat and lubricating oil can be recovered. For gas turbine engines, approximately 29% of the heat input is used for power, and 71% is lost due to exhaust emissions. For cogeneration systems, 40% to 60% of the exhaust gas is typically recyclable.
In a cogeneration configuration, TRICONEX 2000417 has two different cycles: the top cycle and the bottom cycle. In the top circulation system, electric power is the main product, and residual waste heat is the main driving force. In other words, top cycle power plants use steam turbines to generate electricity, and waste heat is a by-product. During the bottom cycle, the first steam generated is used to power industrial processes, such as steam turbines (primary products), while the lower pressure waste steam is used for power generation (prime movers). Bottom cycle power plants are less common around the world due to the high temperatures required.


Product picture display

TRICONEX 2000417 Module Inventory

 


About us 

Ruichang Mingsheng A company specializing in the sales of module spare parts for world-renowned brands (DCS systems) (robotic systems) (large-scale servo control systems), the company’s products include distributed control systems (DCS), programmable controllers (PLC), MOTOROLA MVME industrial modules, industrial control communication converters (Anybus), remote output/input modules (RTU), industrial computers (IPC), industrial low screen screens (IPC) HMI SCSI (50, 68, 80 Pin) AnyBus (Gateway) has become a global sales enterprise of industrial automation spare parts and components.

Email: onewwww@foxmail.com


Introduction to main products

Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules/cards, controllers, touch screens, servo drives.

Advantages: supply imported original products, professional discontinued parts, fast delivery, accurate delivery time,

Main brands include ABB Bailey, GE/FANC, FOXBORO, Invensys TRICONEX, Bentley BENTLY, A-B Rockwell, Emerson EMERSON, OVATION, MOTOROLA, XYVOM, Honeywell HONEYWELL, Rexroth, KUKA, NI, DEIF, Yokogawa, Woodward WOODWARD, Ryan, Schneider SCHNEIDER, Yaskawa, Moog MOOG, PROSOFT and other brands


reminder

For more products, please contact the email for inquiry onewwww@foxmail.com

This article from the temporal Ming sheng automation equipment co., LTD.,

link: http:www.onewwww.com

TRICONEX 2000417 Module Inventory1